Sourayan Technologies

Analog to RS485 Converter

With the latest data acquisition module, 4 or 8 analog single-ended or differential channels are provided, addressing general industrial applications. Multiple input type versions make it possible to go for U (multi-input: Thermocouples, RTD PT100, Volts, mV, mA), P (RTD PT100 3-wire), T (Thermocouples/mV), or D (DC V/mA). Each channel has 4 programmable soft alarms with LED indicators for monitoring purposes. The isolated version offers total isolation from the RS485 port, thereby improving overall safety and reliability. A PC tool is provided for configuration and parameter setting, leaves the user with very little to do.

With the latest data acquisition module, 4 or 8 analog single-ended or differential channels are provided, addressing general industrial applications. Multiple input type versions make it possible to go for U (multi-input: Thermocouples, RTD PT100, Volts, mV, mA), P (RTD PT100 3-wire), T (Thermocouples/mV), or D (DC V/mA). Each channel has 4 programmable soft alarms with LED indicators for monitoring purposes. The isolated version offers total isolation from the RS485 port, thereby improving overall safety and reliability. A PC tool is provided for configuration and parameter setting, leaves the user with very little to do.

Key Feature
Specification
Number of Channels 4 / 8
Input types Thermocouples: J, K, T, R, S, B, N
RTD: PT 100, 3 Wire
DC mV:
  • Single Ended Input: 0 to 80 mV
  • Differential Input: ±80 mV
DC Volts:
  • Single Ended Input: 0 to 1.25V, 0 to 5V, 0 to 10V
  • Differential Input: ±1.25V, ±5V, ±1V, ±10V
DC mA: 0–20 mA, 4–20 mA
Accuracy ± 0.25% of reading
Corrections
  • Cold-junction compensation for Thermocouples (Accuracy Better than ± 0.5°C)
  • Lead resistance Compensation for RTD (Up to 22 Ohms in each lead)
Range Thermocouple & RTD PT100: Refer Table-1
DC Volts/Current: -30000 to +30000 Counts
Zero Offset User Adjustable over Full Range for each Channel
ADC 16 Bit (±32,768 Counts), Sigma-Delta (ΣΔ)
Sampling time Version U: 250 mS Per Channel (4 samples/sec)
Version P: 333 mS Per Channel (3 samples/sec)
Version T: 100 mS Per Channel (10 samples/sec)
Version D: 100 mS Per Channel (10 samples/sec)
Input Resistance Differential Mode > 20MΩ, Common Mode > 10MΩ
Common mode Rejection > 100dB at 50 / 60 Hz
Input Protection ESD: 8KV, EFT: 2KV, Surge: 1KV
Input Conditioning First Order Analog R-C Low Pass Filter
Isolation (Optional) All Channels isolated from RS485 port
1500VAC for 1 second or 250VAC continuous
Port RS485, 2-wire, half duplex, start-stop synchronized
Protocol Modbus RTU
Baud Rate Settable: 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity Settable: None, Even, Odd
Max Units per loop 31
Type Switch Mode (SMPS)
Line Voltage 20 ~ 32 VDC, Nominal 24VDC @ 350mA Min
Note: In case of looping multiple modules on one power source, make sure that the source is capable of supplying minimum 350mA current per module
Consumption 3VA Max
Mounting DIN rail
Overall Dimensions 22.5(W) X 101(H) X 119(D), mm
Terminals Screw Type, Pluggable
Weight 400gm, Approx
Operating Ambient 0 to 55 ºC & 5 to 90% RH Non-condensing
Storage Temperature -10 to +70 ºC
Atmospheres Not suitable for use in corrosive or explosive Atmosphere. The panel in which the instrument is mounted must be free of
Weight 400gm, Approx
Specification
Number of Channels 4 / 8
Input types Thermocouples: J, K, T, R, S, B, N
RTD: PT 100, 3 Wire
DC mV:
  • Single Ended Input: 0 to 80 mV
  • Differential Input: ±80 mV
DC Volts:
  • Single Ended Input: 0 to 1.25V, 0 to 5V, 0 to 10V
  • Differential Input: ±1.25V, ±5V, ±1V, ±5V, ±10V
DC mA: 0–20 mA, 4–20 mA
Accuracy ± 0.25% of reading
Corrections
  • Cold-junction compensation for Thermocouples (Accuracy Better than ± 0.5°C)
  • Lead resistance Compensation for RTD (Up to 22 Ohms in each lead)
Range Thermocouple & RTD PT100: Refer Table-1
DC Volts/Current: -30000 to +30000 Counts
Zero Offset User Adjustable over Full Range for each Channel
ADC 16 Bit (±32, 768 Counts), Sigma-Delta (ΣΔ)
Sampling time Version U: 250 mS Per Channel (4 samples/sec)
Version P: 333 mS Per Channel (3 samples/sec)
Version T: 100 mS Per Channel (10 samples/sec)
Version D: 100 mS Per Channel (10 samples/sec)
Input Resistance Differential Mode > 20MΩ, Common Mode > 10MΩ
Common mode Rejection > 100dB at 50 / 60 Hz
Input Protection ESD: 8KV, EFT: 2KV, Surge: 1KV
Input Conditioning First Order Analog R-C Low Pass Filter
Isolation (Optional) All Channels isolated from RS485 port
1500VAC for 1 second or 250VAC continuous
Port RS485, 2-wire, half duplex, start-stop synchronized
Protocol Modbus RTU
Baud Rate Settable: 2400, 4800, 9600, 19200, 38400, 57600, 115200
Parity Settable: None, Even, Odd
Max Units per loop 31
Type Switch Mode (SMPS)
Line Voltage 20 ~ 32 VDC, Nominal 24VDC @ 350mA Min
Note: In case of looping multiple modules on one power source, make sure that the source is capable of supplying minimum 350mA current per module
Consumption 3VA Max
Mounting DIN rail
Overall Dimensions 22.5(W) X 101(H) X 119(D), mm
Terminals Screw Type, Pluggable
Weight 400gm, Approx
Operating Ambient 0 to 55 ºC & 5 to 90% RH Non-condensing
Storage Temperature -10 to +70 ºC
Atmospheres Not suitable for use in corrosive or explosive Atmosphere. The panel in which the instrument is mounted must be free of
Weight 400gm, Approx
Ordering Info

4 Channel Analog to Modbus 485 Converter —————————————————– SAIC-4C

8 Channel Analog to Modbus 485 Converter —————————————————— SAIC-8C

IP-65 box with mounting accessories and cable glands for converter as shown in the below photographs on
additional cost.

Analog to RS485 Converter